What size breaker do i need for 4500 watts?

30 Amp dual pole breaker and 10 Gage wire size are required for 4500 watt elements.

How big of a breaker do I need for 4500 watts?

The right circuit breaker for this appliance with 4500 watts at 240 volts is either 25 amps or 30 amps. If the water heater isn’t rated as “continuous load”, then it would have been fine to use 100% of the circuit breaker’s rating.

How many amps is 4500 watts?

In an electric circuit of 240 volts, 4500 watts is equivalent to 18.75 amps.

What size breaker do I need for a 5000 watt water heater?

How to calculate water heater wire and breaker size

No. Water heater element power (W) Circuit breaker (A)
5 3,000 20
6 4,000 25
7 4,500 30
8 5,000 35

What size breaker do I need for 6000 watts?

If you have a heater that uses a total of 6000 watts in a 240 volt connection, you’ll need a minimum of 25 Amps. However, because the system will use all 25 Amps, it’s safer to get a circuit breaker of 30 Amps.

Can you replace a 5500 watt element with a 4500 watt element?

You can definitely replace 4500 watt with 5500 watt and get 4-7 gallons more hot water from a tank.


What circuit breaker do I need for Geyser?

A usual house DB will have a rated main circuit breaker (“main switch”) of 60A. Light circuits are normally 10A, geyser circuits 15/20A, plug circuits 15/20A, stove circuits 35A.

What size breaker do I need for a dual 4500 watt water heater?

30 Amp dual pole breaker and 10 Gage wire size are required for 4500 watt elements.

What size breaker do I need for a 20 gallon electric water heater?

Electric water heaters require a dedicated 240-volt dedicated 30-amp circuit and a 10-2 non-metallic (NM) or MC cable. This means the breaker only powers the water heater and no other appliances. A 30-amp circuit breaker can power all 4500watt water heaters regardless of gallon size.

What size breaker do you need for an electric stove?

The industry standard for an electric stove is a 50 amp double-pole circuit breaker.

How many amps does a 5000 watt heater use?

It is dependent on the voltage source. If it a single or three phase power supply. It works out to 5000w/360 = 13.8 amps.

What size breaker do I need for a 4000 watt heater?

The appropriate circuit breaker capacity for a 4000-watt heater is 20 amps if it’s attached to a 240-volt outlet. If you use a lower-amp breaker for this heater, it will cause the electrical system to overload and the breaker to trip.

What size breaker do I need for a 5500 watt hot water heater?

Meanwhile, an 80-gallon heater powered by 5500 watts and 240 volts, will result in 5500W/240V x (1.25 continual load) = 28.64 amps. Meaning, a 30-amp dedicated circuit breaker is enough.

What size wire do I need for 5000 watts?

More likely you would be direct wiring such a heater, so probably 240V with a 30A breaker (30A * 240V = 7200W) This is in the neighborhood of a typical electric clothes dryer. Bonus sub answer, you need to use #10 wire or larger to wire this heater.

How many watts can a 60 amp breaker handle?

The amount of power that each circuit can handle is the number of volts (usually 120) times the number of amps. Therefore, that 60 amp circuit can handle 7200 watts.

What size breaker do I need for a 3000 watt heater?

For the 3000W unit you have, you will require a 20A double pole breaker (240V) and 12/2 w/ground cable. The NEC requires that the branch circuit supplying a storage type water heaters be rated at not less than 125% of the nameplate rating.

How many amps is 5500 watts?

So, 5500 watts / 220 volts X 0.80 = 20 amps.

What’s the difference between a 4500 watt and a 5500 watt water heater?

Generally, a 4500 Watt heater heats about 18 to 25 gallons every hour. 5500 Watt water heaters can heat about 25 to 35 gallons of water every hour.

Can I use a 4500 wattage element in my water heater?

It is ok to install higher watt up to 5500 on 4500 watt heater if breaker is 30 amp and wire is 10 gauge. It is ok to install lower watt: replace 4500 with 3500 as long as voltage is same. Lower watt means less heat, so element can last longer.

What size breaker do I need for a 3500 watt water heater?

You have to have a 30 Amp 2-pole breaker and a 10 AWG wire.

What amps does a geyser use?

Now the watts required by the water heater also depend on the brand and the model of the geyser. But, nearly all electric geysers in the market require power ranging between 16-25 ampere.

Can I use a 40 amp breaker for water heater?

Can I use a 40 amp breaker for a water heater? – Quora. Yes, if AND ONLY IF the wires from the breakers to the water heaters are sufficient to carry 40 amps (e.g. 8-gauge 90C THHN copper). The largest residential heating elements for a tanked water heater are 7000 watts.

What size breaker do I need for a tankless water heater?

Typical tankless requires 40-50 amp breaker for each wire.

Can I use a 40 amp breaker on 10 gauge wire?

Of course you CAN, but it is not safe. A 40 amp breaker will not sufficiently protect a #10 wire, possibly causing a fire. #8 copper wire is appropriate for a 40 amp breaker.

Can I use 12 gauge wire on a 30 amp breaker?

You should not use a 30-amp circuit breaker on a 12-gauge wire. The circuit breaker installed on a circuit is of a specific size to protect a certain wire gauge. A larger breaker on a thinner wire will allow more current over the wire before tripping.

How many amps is a double pole 30 amp breaker?

This shows that each leg of 30 amp double breaker delivers 30 amps, and not 15 amps. . If a 30 amp double pole breaker was 15 amps on each leg, then a 20 amp double breaker would be 10 amps on each leg. And a 15 amp double breaker would be 7.5 amps on each leg.

What size wire would you run for a 30 amp breaker connected to a electric water heater?

Electrical wires

Since the generic breaker size for water heaters is 30-amps, the best wire size is a #10 American Wiring Gauge (AWG).

What does a 240V breaker look like?

This breaker looks like two standard breakers stacked on top of each other, and therefore requires that two breaker positions be open. While the breaker provides this higher voltage, it operates as two linked 120V circuits. Each 240V circuit has two hot wires as opposed to only one.

Can I use a 60 amp breaker for a stove?

Oven Breaker Size Depends on Current Draw

A standard kitchen range with four burners and an oven could draw 30, 40 or 50 amps. But a large commercial unit, or one with features like a convection oven or quick-heat burners, draw 50 to 60 amps.

Can I use a 60 amp breaker for a 50 amp stove?

Yes that will be fine. But the breaker is NOT there to protect your stove. It is there to protect your house wiring. If the cable from the switch panel to your stove is rated for 50 amps or more then that is fine.

Can I use a 50 amp breaker for a 40 amp stove?

Using a 50A plug and receptacle is allowed on a 40A circuit because of an exception in the Electrical Code. The exception is because 40A receptacles do not exist, or rather, are not part of the NEMA standards.

How do you wire a 5000 watt heater?

How to Install a Garage Heater | A DIY Guide – YouTube

How many amps does a 6000 watt heater draw?

For example, a 6,000-watt electric flugelhorn on a 120-volt circuit would require a 50-amp circuit (6,000 watts divided by 120 volts = 50 amps).

How many heaters can you run on a 20 amp circuit?

A 20-amp breaker can support any combination of heaters up to a total of 3,840 watts. For example, using a single thermostat, the breaker could support two 1500-watt heaters or three 1000-watt heaters.

How many amps does a 4800 watt heater use?

4800w / 220v = 22 Amps is just over the ampacity of #12 awg, gotta use #10 awg.

How many watts can 20 amp breaker handle?

20-amp 120-volt circuit: 20 amps x 120-volts = 2,400 watts.

Is a double 20 amp breaker 40 amps?

Nope. It means that two 20 A breakers are ganged together to protect a circuit using two hot wires. Tripping either one at 20 A will trip both to prevent a safety situation where live voltage can be found in the device after one breaker tripped.

How many amps is 5500 watts at 120 volts?

In case of 120 or 240 volts, a 5500 watt generator provides 45 Amps.

What size breaker do you use for a 50 gallon water heater?

The standard for water heater circuits is #10, two conductors with ground (10/2) and a 30 amp circuit breaker for a water heater.

What size breaker do I need for a 3800 watt water heater?

The 3800 can be wired with 12/2 wire and a 20 amp breaker.

How many watts can a 15 amp circuit breaker handle?

On average, a 15 amp breaker can run a one 1K light each without blowing or about 1800 – 2000 watts. The only issue with relying on this formula is that it is advisable to only load a breaker up to 80 percent of its capacity.

What size wire should I use for a 15 amp breaker?

A 15-amp circuit is usually served by 14-gauge wire and is protected by a 15-amp circuit breaker or fuse. A 20-amp circuit, protected by a 20-amp breaker or fuse, must be served by 12-gauge or 10-gauge wire.

What wire do I use for a 60 amp breaker?

For 60 ampere breakers, electricians and professionals suggest using a wire size gauge ranging from 6 AWG to 4 AWG. All household wires have a rating of at least 600V, so only amperage really matters when it comes to determining wire gauge.