What size breaker do i need for a water heater?

Electric water heaters require a 240-volt dedicated circuit, which serves only the water heater and no other appliances or devices. The circuit wiring typically includes a 30-amp double-pole breaker and 10-2 non-metallic (NM) or MC cable.

What size breaker do I need for a 40-gallon electric water heater?

With our answer, a 40-gallon water heater needs at least a 25-amp breaker, the closest to the amperage value. However, I highly recommend using 30-amps for a safer breaker size.

Can I use a 40 amp breaker for water heater?

Can I use a 40 amp breaker for a water heater? – Quora. Yes, if AND ONLY IF the wires from the breakers to the water heaters are sufficient to carry 40 amps (e.g. 8-gauge 90C THHN copper). The largest residential heating elements for a tanked water heater are 7000 watts.

What size breaker do I need for a 220 hot water heater?

You’ll need a 25 or 30 amp circuit breaker. The 30 amp is universally used because the minimum rating of 220 volts exceeds the 25 amp breaker.

What size breaker do you use for a 50 gallon water heater?

The standard for water heater circuits is #10, two conductors with ground (10/2) and a 30 amp circuit breaker for a water heater.

What size breaker do I need for a 4500 watt hot water heater?

The right circuit breaker for this appliance with 4500 watts at 240 volts is either 25 amps or 30 amps. If the water heater isn’t rated as “continuous load”, then it would have been fine to use 100% of the circuit breaker’s rating.


How many amps should a hot water heater pull?

What is the Standard Amperage for an Electric Water Heater? Most electric water heaters use 18.8 amps with 240 volts and a 4,500 watt heating element. A gas water heater uses less amps—about 12 Amps with 115 volts. The average residential container heater has a 40-gallon tank and usually requires a 30-amp breaker.

Can you use 30 amp breaker 40 amp water heater?

No problem. If you really want the 40 amp breaker check the wire size going to your 30 amp breaker (see above advice from ratchet freak: “you will need to know the gauge of the wire all the way from the breaker to the heater.”) If it is #10 wire you’d have to re-wire with #8.

What happens if you oversize a breaker?

They are designed to fail safely. Fuses burn literally, breakers safely discontinue the circuit. If they are oversized, they may not be the weakest points anymore. In case of failure they won’t be the first to burn – it may be the most expensive device you own or, even worse, it may be a conductor in the wall.

What size breaker do I need for a 30 gallon water heater?

The branch circuit needs to be calculated at 125% of the rated ampacity for this type of water heater to be considered a continuous load. In order to work on a 20 Amp OCPD, you will need a 25 or 30 Amp circuit.

How many amps is a double pole 30 amp breaker?

This shows that each leg of 30 amp double breaker delivers 30 amps, and not 15 amps. . If a 30 amp double pole breaker was 15 amps on each leg, then a 20 amp double breaker would be 10 amps on each leg. And a 15 amp double breaker would be 7.5 amps on each leg.

What size wire would you run for a 30 amp breaker connected to a electric water heater?

Electrical wires

Since the generic breaker size for water heaters is 30-amps, the best wire size is a #10 American Wiring Gauge (AWG).

What does a 240V breaker look like?

This breaker looks like two standard breakers stacked on top of each other, and therefore requires that two breaker positions be open. While the breaker provides this higher voltage, it operates as two linked 120V circuits. Each 240V circuit has two hot wires as opposed to only one.

Can I use 10 3 wire for a hot water heater?

Can I Use 10 3 Wire For A Hot Water Heater? You can use 10/3 wire. Use the red and black wires as hot conductors. The ground wire will run to the green screw.

How many amps does a 50 gallon electric water heater use?

A typical 50 gallon electric water heater runs at 4500 watts. In an electric circuit of 240 volts, 4500 watts is equivalent to 18.75 amps.

What size breaker do I need for an electric heater?

Multiply the value for current by 125 percent to determine the size of the breaker you need for the heater. A 1500-watt heater on a 120-volt circuit thus needs a breaker of 15.6 amps. Because a 15-amp breaker would be too small, you need a breaker with the next highest rating, which is 20 amps.

What size breaker do I need for a 3500 watt water heater?

You have to have a 30 Amp 2-pole breaker and a 10 AWG wire.

How many watts can a 30 amp breaker handle?

30-amp 240-volt circuit: 30 amps x 240 volts = 7,200 watts.

How many amps is 5500 watts at 240 volts?

So in this case the 5500 watts would be divided by 240 volts, which would equal 22.9 amps.

Is there a breaker on a hot water heater?

You can cut off power to your hot water heater in either one of two ways: Locate your water tank and turn the power to it OFF by pulling the electrical plug out of the wall socket. Another way to turn the power off is to flip the circuit breaker (the breaker that’s labeled “water heater”) to the OFF position.

How many amps is a 40 gallon electric water heater?

An average 40-gallon electric water heater runs at 240 volts and a wattage of 2500 W. Hence, calculating the amperage 2500/240, we can deduce the amperage is 18.75 A.

How many amps does a Rheem water heater use?

RHEEM 240V General Purpose Electric Tankless Water Heater, 8,000 W Watts, 33 A Amps – Water Heaters – 53UJ83|RTEX-08 – Grainger.

What is a 40 amp breaker used for?

Double-pole breaker

The 15-amp and 20-amp breakers often handle baseboard heaters, 30-amp serve water heaters and electric dryers, 40- and 50-amp are for electric ranges, and the 70-amp could serve a large air conditioner or a subpanel.

What size breaker do I need for a 60 gallon water heater?

All water heater models are compatible with the 2-10 copper wire and 30-amp breaker combination.

Can I use a bigger circuit breaker?

When the breaker is tripping, it is almost never a good idea to replace it with a larger one. Here’s why: It increases the risk of fire. If the breaker is tripping because it’s overloaded (say, drawing 25 amps on a 20-amp breaker), increasing the size may cause the wire or the receptacle to overheat.

Is it OK to oversize the wire and breaker?

yes, as long as it fits under the breaker lugs it is fine. Many times wire is oversized due to long distance pulls resulting in increased voltage drop. The thing you cannot do is undersize the wire for the rated breaker it is under.

What can you run on a 20 amp breaker?

The 20-Amp Circuit

A typical circuit of 20 amperes (amp) is enough to power a bedroom or two. It is a common amp rating used in devices such as outlets and overhead lights, along with a 15-amp circuit. Different amps suit different wire sizes. The 15-amp Circuit, for example, is compatible with a 14-gauge wire.

How much does a 30 amp breaker cost?

The average cost to install a new circuit breaker is $187. The cost is as low as $130 for 15 amp to 30 amp breakers and as high as $280 for breakers up to 200 amps or when the circuit breaker is an older one with limited availability.

Does a water heater need a GFCI breaker?

However, GFCI protection is not required for receptacles not intended to serve wet bar countertop surfaces, such as refrigerators, ice makers, water heaters, or convenience receptacles that do not supply counter-top surfaces.

Is a water heater 30 amp?

A standard electric water heater requires a 30 amp double pole breaker. These are basically two 15 amp breakers in their electrical panel. In some older homes, only a single 15 amp breaker may be available.

Is a double 30 amp breaker the same as a 60 amp breaker?

A main breaker is the same as any double breaker in the box, except that it supplies power to each busbar. The answer is no if you want to draw 60 Amps off a 30 Amp double breaker.

Is a double pole 50 amp breaker 100 amps?

No. That means that it’s a 120/240 volt system with 2 hot (ungrounded) lines incoming, each at 120 volts to ground, 240 volts phase to phase. The breaker is rated at 100 amps and simply breaks both lines, thus the double switch.

Is a double 20 amp breaker 40 amps?

Nope. It means that two 20 A breakers are ganged together to protect a circuit using two hot wires. Tripping either one at 20 A will trip both to prevent a safety situation where live voltage can be found in the device after one breaker tripped.

How many amps does a 110 hot water heater use?

The standard amperage for an electric water heater is 18.8 Amps with 240Volts, 4500 Watt.

Can you use 12 2 wire for a water heater?

Copper 12/2 wire is rated for a maximum of just 20-amperes and would be inadequate both in current capacity and for lacking a ground wire. Even a small 6-gallon, 1,500 watt water heater would require a 12/2 plus ground wire.

What’s the difference between 220 and 240 volts?

In North America, the terms 220V, 230V, and 240V all refer to the same system voltage level. However, 208V refers to a different system voltage level. In North America, the utility companies are required to deliver split phase 240VAC for residential use. That is two 120VAC (+/- 5 %) legs.

Can a single pole breakers for 220?

The very short answer is – you can’t get 240 volts from a single pole breaker.

What kind of breaker do I need for 240 volts?

According to the National Electric Code heating circuits are considered a continuous load and therefore must be derated by 25%. (For example: a 20 Amp heating circuit cannot have more than 16 Amps of load connected.) 120 Volt heaters require 1-Pole circuit breakers, 240 Volt heaters need 2-Pole breakers.

Can you run Romex to a water heater?

Tip: you do not want the Romex connector to be touching water pipes. You don’t want the temperature of the hot water outlet to compromise your electrical work. Connect the water heater to the circuit – back within the junction box, you will wrap the ground wire around the ground screw and secure it.

What happens if you wire a hot water heater wrong?

To eleminate these hazards connect the wires properly and make sure the frame (tank) of the hot water heater is securely connected to ground( green wire). If properly connected and the heater malfunctions( shorts to ground or opens) it will simply stop heating or open the circuit breaker with an overload.

Does a water heater need a neutral wire?

The conventional hot water heater does not need a neutral at the moment. The neutral wires are included with the 4wire cord for 220 and 240 volt appliances that have electronic controls.

How many heaters can you run on a 30 amp breaker?

The number of heaters you can attach to one thermostat also depends on your circuit and wiring

Volts Size of breaker Maximum watts on circuit
240 20 Amp Double Pole 3840
240 30 Amp Double Pole 5760

How many heaters can you run on a 20 amp circuit?

A 20-amp breaker can support any combination of heaters up to a total of 3,840 watts. For example, using a single thermostat, the breaker could support two 1500-watt heaters or three 1000-watt heaters.

How many amps does a 7500 watt heater draw?

Answer: 31 amps !!!!