What size flex duct should i use?

How do I know what size flex duct I need?

One simply needs a ruler or measuring tape along with the end of the hose or outlet. Keep in mind that you have to begin the measurements from the interior wall of the circle. The distance to the opposing point of the circle is the measure of the flex duct sizing for the inner diameter.

What size duct should I use?

The size of your duct work depends not just on the size of your entire house but also on the size of each individual room. Thus, one needs to gauge the square footage of the entire house as well as that of all the different rooms in order to decide duct work sizing.

What size duct do I need for a 12×12 room?

A 12×12 foot room will need a 4×8 inch supply duct to get an adequate CFM rate, which is about 144 CFM.

How many CFM does a 14 flex duct carry?

CFM Sizing Chart For Flex Round Ducts (50-1,700 CFM)

Duct Size (Inches) Flex Duct Airflow (CFM)
12 inches 480 CFM
14 inches 700 CFM
16 inches 1,000 CFM
18 inches 1,300 CFM

How far can you run 6 inch flex duct?

E.

Flexible duct shall be supported at manufacturer’s recommended intervals, but at no greater distance than four feet. Maximum permissible sag is 1/2 inch per foot of spacing between supports.


What size ductwork do I need for a 3 ton unit?

Multiply the tonnage, 3.5, by the total BTU per ton and this will give you the total BTU rating. Multiply 6 x 42 to determine the duct size of 252 square inches The clear are of the duct must be at least 252 square inches This measurement also includes the opening in the floor at the bottom of the return.

What size ductwork do I need for a 5 ton unit?

Using this approach, two 20-in. x 25-in. return grilles will be the right choice for a five-ton HVAC system in order to actually deliver 2,000 cfm back to the blower without causing the return to hemorrhage.

How many CFM does a 6 inch duct have?

“For example, most techs will tell you that a 6” duct will provide about 100 CFM.”

What happens if ductwork is oversized?

Your system pushes air into the ducts, but the ducts are too large for it to build up any sustained amount of air pressure, and thus a “forced air” system doesn’t have any force. As a result, you get poor air flow and no matter how hard your system seems to be working, you don’t get to feel the benefit.

How many CFM is 100 square feet?

Fan Sizing for Bathrooms Under 100 SQ. FT.

The standard rule for bathrooms 100 square feet or smaller is one CFM per square foot of the bathroom. To find the square footage multiply the length of the bathroom by the width. Example: 10′ x 10′ bathroom = 100 square feet.

Does register size matter?

Unless you are severely undersizing your register, the noise is really the only issue. So a bigger register will not help cool or heat your room better. Putting the register in a better location and making sure the air is shooting out in an efficient manner and at an efficient angle is key.

What is the good rule of thumb in sizing Ductworks?

Determining the Right Duct Size

When you hire a professional to install your ductwork, they’ll often size your HVAC ducts using a rule of thumb that states an air conditioner with one-ton capacity should be installed for every 500 square feet of air-conditioned floor area.

What size duct is needed for 1000 CFM?

Rectangular equivalent diameter for air flows between 100 – 50000 cfm.

Air flow – q – (Cubic Feet per Minute, cfm) (m3/s) Rectangular Duct Sizes (inches) (mm) x (mm) Friction Loss (inH2O / 100 ft duct) (Pa/100m)
1000 (0.45) 10 x 14 12 x 12 0.15
1300 (0.59) 12 x 14 0.15
1400 (0.63) 12 x 15 0.15
1700 (0.77) 10 x 22 14 x 15 0.14

How many CFM is a 4 inch duct?

Reviewing the chart, a 4” pipe will convey 395 CFM at 4500 FPM. This means that a 4” pick-up on a machine will use 395 CFM from the filtering system, or, if you know that a machine will require approximately 400 CFM to remove the waste, you should use a 4” pipe for that purpose.

How many CFM do I need for 500 square feet?

That’s why we need to divide the total volume by 60, hence 4,800/60 = 80 CFM. Answer: You need an 80 CFM airflow (for 300 sq ft standard room and 2 ACH).

CFM Chart For Common Room Sizes.

Room Size: CFM (At 2 ACH)
How many CFM for a 400 sq ft room? 107 CFM
How many CFM for a 500 sq ft room? 133 CFM

What is the max recommended length of flexible duct?

The ASHRAE 2009 Fundamentals Handbook (page 21.7 and 21.18) reads that “for commercial systems, flexible ducts should be… no more than 5 ft in length, full stretched.” 2. This is also included in the more recent 2013 handbook, however, the limiting length recommendation was changed to 6 feet.

How long can you run flexible duct?

It says, “Length limitation: Factory-made flexible air ducts and connectors should not be more than 5 feet (1,524 mm) in length and shall not be used in lieu of rigid elbows or fittings.”

Does Flex duct reduce airflow?

You see, flex duct is rarely installed very well. If you’ve ever seen kinked or sagging flex duct and wondered whether that was a problem, you were onto something! Since flex duct, by definition, is flexible, it often flexes in ways we don’t want it to. The result is poor airflow and ineffective HVAC systems.

Can ductwork be too big?

Too big – Oversized ducts will give the heated or cooled air they carry more time to come to room temperature before they get through the vents and into the room, so you’ll end up with less heating or cooling where you want it, and the system being overworked to meet demand.

What size duct is needed for 1200 CFM?

At 600 CFM, the minimum duct size is 6”. At 900 CFM, the minimum duct size is 8”. Finally, at 1200 CFM and above, consider a 10” diameter duct or larger.

What is the formula for calculating duct size?

To calculate the required equipment size, divide the HVAC load for the entire building by 12,000. One ton equals 12,000 BTUs, so if a house or office needs 24,000 BTUs, it will take a 2-ton HVAC unit. If you get an uneven number, such as 2.33 for a 28,000 BTU load capacity, round up to a 2.5-ton unit.

What size return do I need for a 5 ton unit?

x 25-in. Return grilles are the best choice for a five-ton system in order to deliver 2,000 cfm back to the blower without causing the return to hemorrhage.

How many returns do I need for a 4 ton unit?

(Example: 4 (ton unit) x 144 square inches = 576 squared. The square root of 576 is 24. Therefore, your return air duct and grill size will be 24 by 24 inches.)

How many CFM is a 5 ton unit?

How many cfm for 1 – 5 ton ac unit ?

Cooling Capacity CFM (Airflow)
How many CFM is a 3 ton ac unit? 1050 – 1200 CFM
How many CFM is a 3.5 ton ac unit? 1225 – 1400 CFM
How many CFM is a 4 ton ac unit? 1400 – 1600 CFM
How many CFM is a 5 ton ac unit? 1750 – 2000 CFM

How big does a return air duct need to be?

A typical air return vent size (16×20) can provide airflow with a maximum of up to 1,500 CFM. To achieve that 1,500 CFM, we need a big pressure pushing air through the ducts and through the cold air return grille.

Is it better to undersize or oversize ductwork?

Proper sizing.

All the ducts must be sized to match the HVAC equipment capacity. Using oversized ducts will erode the system’s efficiency, while undersized ducts won’t carry the necessary volume of air.

How do you increase airflow in air ducts?

Increasing airflow in ductwork can be done by cleaning the air filters and ductwork. By adding inline duct booster fans and/or air dampers significantly can improve airflow in weak areas.

Can you have too much return air?

Can an air return be too big? No, an air return cannot be too big, except in extreme cases where a closed room is temporarily under negative air pressure. Return vents maintain air pressure, filter out debris, and are critical to the efficient operation of any HVAC system.

How many CFM do I need for 120 square feet?

For example, for a room that’s 120 square feet and has a 10-foot ceiling: 120 x 10 = 1,200. 1,200 divided by 60 = 20. 20 x 8 = 160 CFM.

How much CFM do I need for 2000 square feet home?

Heat and energy recovery ventilators

Total area of home (square feet) Continuous ventilation rate
1,000 square feet 50 CFM
2,000 square feet 100 CFM
3,000 square feet 150 CFM

How much CFM should a room have?

One cfm per square foot of floor area is the average air quantity required for a room or entire building.

How many CFM is a register?

To keep things simple, round to 180 cfm. If the room had two supply registers, the base supply cfm would be divided between the two registers to determine individual supply register airflow. Since the living room needs a base total of 180 cfm, each supply register should have 90 cfm.

What happens when you reduce duct size?

The key takeaway here is that air moves from a larger to a smaller duct, the velocity increases. When it moves from a smaller to a larger duct, the velocity decreases. In both cases, the flow rate — the amount of air moving through the duct, in cubic feet per minute — stays the same.

What size register do I need?

To measure your register properly, remove the existing register from the floor, wall, or ceiling in which it is installed. Then, measure the length and width of the air duct opening. If the size of the duct measures 4″x10″, for example, then a 4″x10″ register is what you’ll need.

How do you measure HVAC duct size?

Measure the end of a square or rectangular duct each way to determine the size. If the duct fitting inside the wall transitions to a circular duct, measure inside the circular duct from top to bottom. Repeat this at the remaining grills and ducts throughout the house.

How do you calculate CFM for duct size?

Since the size of your ductwork can increase or lower this measurement, you’ll have to find the necessary CFM for each room before you can get the right duct size for each space. Cubic Feet Per Minute = (HVAC Unit Tons x 400) / total square footage of home.

How do I calculate my HVAC plenum size?

  1. For rectangular duct: If size of air conditioner (example: 4 tons) x 144 square inches = return air duct in square inches.
  2. For round duct: If diameter of duct x 3.14 = return air duct in square inches.

How many CFM is a 12 inch duct?

The rule of thumb for a 12 inch duct is 715 cfm.

Can flexible duct be used for range hood?

No. Avoid flexible duct for your range hood, regardless of the CFM. Flexible duct is a poor investment because it is: Not durable/sturdy.

Is a higher CFM better?

A: Airflow quantifies the amount of air a ceiling fan delivers and is measured in CFM which stands for cubic feet per minute. CFM measurements are taken when a fan is on high speed, then that number is divided by the watts used. This means that the higher the CFM, the more efficient the fan, and the more air it moves.

How many CFM do I need HVAC?

350 to 400 CFM per ton of cooling is required for proper air conditioning system operation. For example, if you are checking a 3 ton system, the airflow required is between 1050 and 1200 CFM. Too little airflow, and you will be unable to charge the system properly.

What is the recommended air flow rate for ventilation?

ASHRAE (formerly called the American Society of Heating, Refrigerating and Air-Conditioning Engineers) recommends (in its Standard 62.2-2016, “Ventilation and Acceptable Indoor Air Quality in Residential Buildings”) that homes receive 0.35 air changes per hour but not less than 15 cubic feet of air per minute (cfm) per